GRBL 1.1 Error 10
GRBL 1.1ErrorPosition is kept
You tried to turn soft limits on ($20=1) while homing is off. The controller needs homing to know where its limits are.
Position is kept. An error means the controller refused that one line or command, so nothing moved for it. (Hamrun's reading)
What to do
- Turn homing on first ($22=1), home the machine ($H), then turn soft limits on ($20=1).
- If the machine has no limit switches, leave soft limits off.
- This is not the soft-limit alarm (Alarm 2): no move was refused.
Official GRBL 1.1 message: “Soft limits cannot be enabled without homing also enabled.” source
Got a different message?
Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.
Related codes
- grblHAL Error 10: You tried to turn soft limits on ($20=1) while homing is off. The controller needs homing to know where its limits are.
- uCNC Error 10: You tried to turn soft limits on ($20=1) while homing is off. The controller needs homing to know where its limits are.
Official text copied from the GRBL 1.1 source on 2026-11-01. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.