Grbl_Esp32 Alarm 2

Grbl_Esp32AlarmPosition is kept

A move in the file would take the machine past the travel it knows it has, so the controller refused to start it.

Position is kept. The controller checks the move before making it, so nothing ran into a stop. (Hamrun's reading)
What to do
  1. Unlock ($X). Position is still good.
  2. Check where you set work zero (X0 Y0): the whole job has to fit between that point and the machine's limits.
  3. Make sure the file uses absolute moves (G90) and the job's origin in your software matches where you zeroed.
  4. Leave soft limits on. Move the job or the work zero instead; turning them off only moves the crash to the end stops.
What users reported CLAIMED · forum and issue reports, not official
  • The toolpath sat in negative workspace (outside the machine's travel). The fix was a work offset or moving the job into the machine's space, not turning soft limits off. r/hobbycnc thread, Mar 2026
  • A sender's tool-change routine moved Z past its travel and threw Alarm 2, even on files that didn't need a tool change. Later versions changed the routine. gSender GitHub issue #673
Name in the Grbl_Esp32 source: SoftLimit. The meaning above is in Hamrun's words; Grbl_Esp32's own message text isn't copied here. source

Got a different message?

Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.

Related codes

  • GRBL 1.1 Alarm 2: A move in the file would take the machine past the travel it knows it has, so the controller refused to start it.
  • grblHAL Alarm 2: A move in the file would take the machine past the travel it knows it has, so the controller refused to start it.
  • FluidNC Alarm 2: A move in the file would take the machine past the travel it knows it has, so the controller refused to start it.
  • uCNC Alarm 2: A move in the file would take the machine past the travel it knows it has, so the controller refused to start it.

Code name taken from the Grbl_Esp32 source on 2026-11-10; the meaning is in Hamrun's words and Grbl_Esp32's message text isn't copied. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.