grblHAL Alarm 19

grblHALAlarmNot a position problem

Communication with a Modbus device (often the spindle VFD) timed out or failed.

Not a position problem. Hamrun's reading: this is about the spindle link, not motion. If the job stopped mid-cut, home before trusting position. (Hamrun's reading)
What to do
  1. Check the RS485 cable to the VFD and that the VFD is on.
  2. Check the Modbus address and speed settings match the VFD.
Official grblHAL message: “Modbus exception. Timeout or message error.” source