uCNC Alarm 13

uCNCAlarmPosition is kept

A limit switch triggered while the machine was standing still.

Position is kept. Nothing was moving, so no steps were skipped; uCNC's source notes position was not lost in this case. (Hamrun's reading)
What to do
  1. Find what pressed the switch: a cable chain, a loose bracket, or someone bumping the gantry.
  2. If nothing touched it, the switch wire may be picking up noise: route it away from motor and spindle cables, or use shielded cable.
  3. Reset and unlock ($X) once the switch reads clear.
Name in the uCNC source: EXEC_ALARM_HARD_LIMIT_NOMOTION. The meaning above is in Hamrun's words; uCNC's own message text isn't copied here. source

Got a different message?

Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.

Code name taken from the uCNC source on 2026-11-10; the meaning is in Hamrun's words and uCNC's message text isn't copied. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.